Year |
2018 |
Issue |
386 |
Volume |
4 |
Pages |
139-148 |
Caption |
Calculation and modelling of the converter of constant tension with the intermediate resonant high-frequency inverter |
Authors |
Martynov A.A., Samsygin V.K., Sokolov D.V., Ulitovsky D.I., Kokovinov A.A. |
Keywords |
constant-voltage converter, resonance-based high-frequency inverter, transformer, inductance, capacity, filter, quality factor of resonance circuit |
DOI |
10.24937/2542-2324-2018-4-386-139-148 |
Summary |
Object and purpose of research.Development and justification of calculation procedure for constant-voltage converter with intermediate resonance-based high-frequency inverter Subject matter and methodsAnalytical methods and computer-based simulation of electromagnetic processes in semiconducting constant-voltage inverters. Main results.Computer-based model of converter with intermediate resonance-based high-frequency inverter and the data about its parameters and electromagnetic processes. It was shown that these parameters and processes can be calculated using a grapho-analytical method because the results yielded by it are practically as accurate as those obtained through computer-based simulation. Conclusion.The results of this study make it possible to calculate the parameters of above-mentioned converter with greater accuracy and speed up introduction of these converters to various electric power systems, including marine ones |